1401 H St NW

Renovation of office building located in Washington, DC

1401 H Street

Engenium Group provided Mechanical, Electrical and Plumbing engineering services to support 13,000 SF of renovations to limited public areas, including the main entrance, main lobby, multiple elevator lobbies and lounges, courtyard, penthouse and roof terrace.

In addition, our team completed a vestibule energy analysis and were able to offset 35,000 KWH energy loss from eliminating vestibule with energy savings from parking garage LED lighting. Engenium Group worked closely with DCRA to navigate alternate compliance paths to meet energy and green code requirements.

  • Mechanical
    • New 2,000 cfm, 5-ton water source heat hump for fitness center
    • 6-ton split system heat pumps serving the penthouse and roof terrace
  • Electrical

    New LED light fixtures and code compliant controls

  • Plumbing
    • New domestic water heater to serve roof terrace and lobby amenities
    • Sump drainage for elevator hoistways
Project Details

13,000 SF | 1401 H Street NW, Washington, DC 20005

  • MEP